CaseyJames669
MN Journeyman Sprinkler Fitter Exam Prep
This podcast will focus on the required reference material needed for the MN Journeyman Sprinkler Fitter Exam.
Be sure to visit the podcast's website and support the creator: podcasters.spotify.com
Author
CaseyJames669
Category
Podcast website
Latest episode
Nov 19, 2026
Where to listen?
Podcasts in the app Replaio Radio Coming soonPodcasts are coming to the app soon. Install now and be the first to see a whole new take on podcasts
Episodes
NFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep 19.11.2026 57:54
NFPA 13 Allowable Sprinkler Omissions: Concealed Spaces, Closets, Electrical Rooms, Canopies & Cloud Ceilings | MN Journeyman Exam Prep Allowable sprinkler omissions in NFPA 13: the concealed-space exception list, bathrooms, closets, electrical rooms, canopies and exterior projections, and cloud ceilings. Minnesota rewrites the linen closet and pantry rule and adds vestibule and pool language....
Freeze Protection for Wet Sprinkler Systems: 40°F Rule, Heat Tracing, Dry Sprinklers & Heated Valve Rooms | MN Journeyman Exam Prep 18.11.2026 50:44
Freeze protection for wet systems: the 40 degree rule, every allowed alternate (antifreeze or listed systems, insulation or casings holding 40 to 120, listed and supervised heat tracing, PE heat-loss calcs), dry sprinkler barrel lengths from Table 15.3.1(a), heated valve rooms, freezer piping details, Minnesota's FDC check-valve and vestibule amendments, and NFPA 25 cold-weather duties. Two fitter...
NFPA 13 System Acceptance: Hydrostatic Tests, Air Tests, Flushing & Test Certificates | MN Journeyman Exam Prep 17.11.2026 50:30
System acceptance: hydrostatic testing at 200 psi or 50 over working pressure for 2 hours, the dry-system 40 psi air test for 24 hours with 1.5 psi allowed loss, underground flushing flow rates at 10 ft/s, blank tracking, alarm and dry-trip tests, and the Contractor's Material and Test Certificate. Plus Minnesota's 5 psi water-supply margin and 36-month flow test amendment. Two fitters, a...
NFPA 25 Weekly & Monthly ITM: Control Valves, Gauges, Dry & Preaction Valves, Fire Pumps & Cold-Weather Checks | MN Journeyman Exam Prep 16.11.2026 52:58
NFPA 25 weekly and monthly inspections: the control valve ladder (sealed weekly, locked/supervised monthly), backflow and RPZ checks, dry and preaction valve enclosures and compressors, gauges, fire pump weekly/monthly items, cold-weather daily checks, and the Minnesota fire code's 901.6.1 maintenance rule. Two fitters, a lot of swearing (18+), a lightning round, and a Christmas war story about a...
NFPA 13 ESFR Sprinklers: Installation, Spacing, Deflector Distances & Obstructions | MN Journeyman Exam Prep 15.11.2026 50:51
ESFR installation: 100 sq ft maximum and 64 sq ft minimum per sprinkler, 12/10 ft spacing, 8 ft minimum, 30 ft ceiling and 25 ft storage limits, roof slope, deflector distances by K-factor, the obstruction table, draft curtains, and 36 in. clearance to storage. Design pressures (Chapter 23) are NOT covered in this episode. Two fitters, a lot of swearing (18+), a lightning round, and a war story ab...
NFPA 13 Test Connections & Pressure Gauges: Inspector's Test, Trip Test Manifolds & Gauge Rules | MN Journeyman Exam Prep 14.11.2026 50:37
Inspector's test connections, trip test manifolds, and pressure gauges. Wet-system test connection anywhere downstream with the smallest K-factor, dry-system test at the far end with brass fittings, the 15 s and 60 s water-delivery rules, gauge locations, quarter-inch gauge valves, twice-working-pressure range, and NFPA 25 gauge replacement or calibration (within 3% of full scale, every 5 years)....
NFPA 13 Drainage: Main Drains, Auxiliary Drains, Pipe Pitch & Drain Sizing | MN Journeyman Exam Prep 13.11.2026 48:25
Drainage: main drains, auxiliary drains, and pipe pitch. Half-inch and quarter-inch per 10 ft, everything half-inch in refrigerated areas, the drain sizing table (3/4, 1-1/4, 2 in.), auxiliary drain tiers by trapped gallons, drum drips, drain discharge, the 4 ft of heated pipe rule, and NFPA 25 main drain testing (annual, quarterly behind backflow/PRV, the 10% drop). Two fitters, a lot of swearing...
NFPA 13 Control Valves: Listed Indicating Valves, PIVs, Check Valves & Supervision | MN Journeyman Exam Prep 12.11.2026 51:17
Control valves: listed indicating valves, PIVs and wall PIVs, check valves, and the four ways to supervise a valve. We cover valve location and accessibility, no shutoff in the FDC line, valves on both sides of a check, PRVs at 175/165 psi with the half-inch relief, PIV height of 32 to 40 inches above grade, floor control assemblies, Minnesota's locked-open valve security rule, and NFPA 25 valve I...
Hydraulics for the MN Exam: Hazen-Williams, C-Factors, Friction Loss & Equivalent Length | MN Journeyman Exam Prep 11.11.2026 49:42
The Hazen-Williams formula in plain English, the C-factor table (100, 120, 140, 150), why the fitting table is "C = 120 only" and how the multipliers work, equivalent lengths for elbows, tees, and valves, what's in and out of the calc, feet of head vs. psi, and K = Q/√P with worked examples. Minnesota adopts NFPA 13-2016 (Hazen-Williams is 23.4.2.1.1 there), and we flag it. Plus a war story about...
NFPA 13 High-Piled Storage & Commodity Classification: Classes, Arrays & Ceiling Sprinklers | MN Journeyman Exam Prep 10.11.2026 49:07
Class I through IV, Group A/B/C plastics, cartoned vs. exposed, the 5/15 and 5/25/40 percentage rules, plastic pallets, open vs. closed arrays, rack types, flues, mixed commodities, and the general information sign. Minnesota adopts NFPA 13-2016, so we flag the 2016 numbers alongside 2019. Plus a mattress-warehouse war story about what happens when the stuff in the boxes changes and nobody reads t...
NFPA 13 Water Supplies: Duration, Hose Stream Allowances & Pressure Requirements | MN Journeyman Exam Prep 09.11.2026 46:02
Is there enough water, for long enough? At least one automatic supply, what counts as a supply, the 6-inch private main rule, pressure tanks, a live two-hydrant flow test (static, residual, measure the outlet), 0.433 psi per foot and 2.31 feet per psi, then the two evil-twin tables: hydraulically calculated hose stream and duration (100/250/500 gpm; 30, 60-90, 90-120 min) vs. pipe schedule (15 or...
NFPA 13 Wet Pipe Systems: Alarm Check Valves, Retard Chambers & Waterflow Alarms | MN Journeyman Exam Prep 08.11.2026 44:15
The plain-Jane system nobody studies. How an alarm check valve and retard chamber actually work (and why a plugged retard drain makes the outside bell ring like a drunk church), gauges above and below the check, the relief valve "175 psi or 10 over, whichever is greater," the more-than-20-sprinklers local alarm, 3/8-inch vs. 3/4-inch alarm piping, the 3/4-inch strainer, alarm bypass test connectio...
NFPA 13 Obstructions to Spray Patterns: Continuous, Noncontinuous & Shadow Areas | MN Journeyman Exam Prep 07.11.2026 45:19
Eighteen inches below the deflector splits the whole chapter. Above it, the spray pattern's still developing: the three times rule (24-inch cap, but not for columns), "structural members only" in light and ordinary hazard, straddling obstructions up to 4 ft, trusses, the beam table, wall soffits, ceiling fans and privacy curtains. Below it, the spray can't reach the hazard: fixed obstructions over...
NFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners (Non-Seismic) | MN Journeyman Exam Prep 06.11.2026 47:15
Holding the pipe up, no sway bracing. Five times water-filled plus 250 lb vs. what the building has to carry, listed vs. unlisted parts, rod and U-hook sizes, fasteners in concrete, steel and wood (powder-driven 750/1000/1200 lb), toggles, metal deck, trapezes, the max-spacing table for steel, lightwall, copper and CPVC, end-head and armover limits (and the over-100-psi twelve-and-six rule), mains...
NFPA 13 Sprinkler Spacing & Protection Area: Light, Ordinary & Extra Hazard | MN Journeyman Exam Prep 05.11.2026 44:39
How far apart, how far off the wall, and how much floor one standard spray head is allowed to cover. We walk the S x L method, the light/ordinary/extra hazard and storage tables (that cursed 168 sq ft row), the 225 vs. 400 sq ft caps, four-inch and six-foot minimums, baffles, small rooms, angled walls, and a pile of worked layouts. Two fitters, a lot of swearing (18+), a lightning round, and a war...
NFPA 2001 Clean Agents & MSFC 904.10: Design Concentration, Discharge Time, Hold Time & Inspections | MN Journeyman Exam Prep 04.11.2026 44:20
Clean agent systems: NFPA 2001 and Minnesota 904.10. Halocarbons vs. inert gases, safety factors, the 10-second discharge, the 85%/10-minute hold, abort vs. manual release, and the six-month container check with the Minnesota tag. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and check your...
NFPA 72 & MSFC 903.4 Sprinkler Supervision: Waterflow, Tamper, Supervisory Signals & Exterior Alarms | MN Journeyman Exam Prep 03.11.2026 42:58
The alarm side of sprinklers: NFPA 72 and Minnesota 903.4. Waterflow in 90 seconds, tamper switches in two turns, supervisory pressure, level and temperature numbers, test frequencies, and exactly what Minnesota says must be supervised. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and chec...
NFPA 20 Fire Pumps & MSFC 913: Suction, Relief Valves, Pump Rooms & Acceptance Tests | MN Journeyman Exam Prep 02.11.2026 46:03
Fire pumps, NFPA 20 and Minnesota 913. Suction rules that keep pumps alive (zero psi at 150%, OS&Y only within 50 feet, ten pipe diameters, eccentric reducers), circulation and pressure relief valves, pump room protection, and the acceptance test. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differ...
NFPA 14 Standpipes & MSFC 905: Classes, Pressures, Flows & Minnesota Hose Connections | MN Journeyman Exam Prep 01.11.2026 46:42
Standpipes, NFPA 14 and Minnesota 905. Classes I, II and III, wet vs. dry vs. manual vs. semiautomatic, pressure limits and PRVs, flow rates, and Minnesota's own modification for non-high-rise buildings. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and check your exam's edition. App news:...
NFPA 10 Portable Fire Extinguishers: Ratings, Placement, Inspection & Hydro | MN Journeyman Exam Prep 31.10.2026 49:46
Halloween special: portable fire extinguishers. Ratings, placement and travel distance, monthly inspections, annual maintenance, and hydro intervals under NFPA 10 and MSFC 906. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and check your exam's edition. App news: the MN Journeyman Exam Prep...
NFPA 24 Underground Mains: Bury Depth, Thrust Restraint, Flushing & Hydro | MN Journeyman Exam Prep 30.10.2026 47:26
Underground private fire service mains: bury depth, thrust blocks and restraint, flushing flows, and the hydro test. Everything that goes in the dirt before the riser. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and check your exam's edition. App news: the MN Journeyman Exam Prep Android...
NFPA 22 Water Tanks: Heating, Suction Tanks, Vortex Plates & Levels | MN Journeyman Exam Prep 29.10.2026 51:14
Water tanks for fire protection, the NFPA 22 way. We dig into tank heating and the 40-degree rule, suction tanks, vortex plates, and the level and temperature supervision numbers that show up on the Minnesota journeyman exam. The usual: two fitters, a lot of swearing (18+), a lightning round of exam tips, and a war story that is mostly true. Minnesota law wins where it differs, and check your exam...
Seismic Protection: Flex Couplings, Clearance, Sway Bracing & Restraint | MN Journeyman Exam Prep 28.10.2026 19:01
Seismic protection for sprinkler piping, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins NFPA 13-2016, where this is section 9.3. NFPA 13-2019 moved it to Chapter 18. The big numbers are the same in both editions, and we flag what 2019 added. Whether a building needs seismic protection comes from the building code, the engineer and the AHJ. NFPA 13 covers how to do it. Covered:...
NFPA 13R Low-Rise Residential | MN Journeyman Exam Prep 27.10.2026 28:34
NFPA 13R, sprinklers for low-rise residential buildings (apartments, hotels, dorms, board and care), for the Minnesota journeyman sprinkler fitter exam. Every number comes from NFPA 13R-2016, the newest edition we could verify. Check newer editions if your exam uses them. When Minnesota allows 13R (MSFC 903.3.1.2: up to four stories and 60 ft, podium buildings measured from the podium deck). Cover...
NFPA 13D One- & Two-Family Dwellings | MN Journeyman Exam Prep 26.10.2026 34:19
NFPA 13D, sprinklers for one- and two-family dwellings and manufactured homes, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins 13D-2016 (Minn. R. 7511.8000); we map it to 13D-2019. When Minnesota requires house sprinklers (MSFC 903.2.8: R-3 dwelling units of 4,500 sq ft and up, excluding garages) and when 13D is allowed (903.3.1.3); purpose (prevent flashover in the room of orig...