Listen as Nationally Recognized Electrical Code Experts interpret and explain in technical detail the various chapters, sections, parts, and line items of the National Electrical Code. If you struggle with technical jargon then follow me and consider joining our Fast Trax® Family. We have introduced (2) new affordable NEC Learning Programs to teach you the National Electrical Code. Visit our website at https://fasttraxsystem.com for more details. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support .

Be sure to visit the podcast's website and support the creator: fasttraxsystem.com

Author

Paul W. Abernathy

Category

Education

Podcast website

fasttraxsystem.com

Latest episode

Nov 12, 2026

Where to listen?

Podcasts in the app Replaio Radio Coming soon

Podcasts are coming to the app soon. Install now and be the first to see a whole new take on podcasts

Get it on Google Play Install for free Android 10M+ downloads · 4.7+ rating iOS soon

Episodes

Let's Ask Paul | Episode 78 | Equipotential bonding grid and Multifamily dwellings questions 29.08.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers a few questions submitted via the Let’s Ask Paul Portal at www. PaulAbernathy.com . In this episode, Paul answers a question on the 3’ perimeter grid in 680.26(B)(2) and then tackles a question about 60 amp services to apartments. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-po...

CAMP CMECP | Exciting News for CMECP 28.08.2022

Listen as Paul Abernathy talks about the CMECP Program and the live stream on Monday. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support . Struggling with the National Electrical Code? Discover the real difference at Electrical Code Academy, Inc. —where you’ll learn from the nation’s most down-to-earth NEC expert who genuinely cares about y...

Let's Ask Paul | Episode 77 | Portable Generators, Sizing Parallel EGC, and Dissection of Questions 20.08.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers a few questions submitted via the https://www. PaulAbernathy.com portal. The questions were about portable generators and optional power to dwellings, sizing the EGC for parallel applications and when you must increase the size of the EGC, and lastly Paul answers a question about his method to dissecting an exam que...

Let's Ask Paul | Episode 76 | Voltage Drop Why, HCF Receptacle Locations, and Myers Hubs 07.08.2022

Welcome to another episode of Let's Ask Paul, the podcast dedicated to answering your questions on the National Electrical Code. On this episode Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers questions about receptacles in health care facilities and their placements, Myers hubs, and a deep understanding of Voltage Drop and the increasing of the equipment grounding conduct...

Let's Ask Paul | Episode 75 | Number of branch circuits on 15 or 20 and more. 03.08.2022

Listen as Paul Abernathy answers more questions submitted via PaulAbernathy.com. In this episode Paul answers questions on how to calculate the minimum number of receptacles on branch circuits. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support . Struggling with the National Electrical Code? Discover the real difference at Electrical Code A...

Let's Ask Paul | Episode 74 | Cabin Disconnects, GFCI and Dryer Issue, and Lutron Panels 03.08.2022

Listen as Paul Abernathy answers more questions submitted via PaulAbernathy.com. In this episode Paul answers questions on GFCI issued with Dryer, installing an outside service disconnect for a cabin and multiple Lutron panels and possible tap rules. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support . Struggling with the National Electrica...

Let's Ask Paul | Episode 73 | SEU and Bare Conductors and Rods at Detached Structure 25.07.2022

Listen as Paul Abernathy answers more questions submitted via the Let's Ask Paul Portal at www. PaulAbernathy.com . Today's question is about what do to when a service panel becomes a remote distribution panel (Subby Bruh) and it has existing SE-U cables. Paul will also answer a question about ground rods at a detached structure as well in this episode. Become a supporter of this podcast: https://...

Electrify Podcast | Going Above the Minimum Standard of the National Electrical Code 18.07.2022

Listen as Paul Abernathy, the CEO and Founder talks about when is it OK to go above the minimum safety standards of the National Electrical Code. Paul also talks about electrical inspectors and even tells a story about how an electrical inspector died after working one day on the job. If you want or care to know Paul's opinion of going above the NEC then you will enjoy this episode. Become a suppo...

Let's Ask Paul | Episode 72 | Can GFCI Devices protect receptacle and circuits where no EGC Exists? 16.07.2022

Listen as Paul Abernathy, Certified Master Electrical Code Professional and CEO and Founder of Electrical Code Academy, Inc. answer more questions submitted through the Let's Ask Paul Portal at www. PaulAbernathy.com . In this episode Paul gets asked if a GFCI Device, such as a circuit breaker type or receptacle type OK to protect the branch circuit and receptacle when a non-grounding type is repl...

Let's Ask Paul | Episode 71 | WR on USB Devices, Apology OK, Raceway Studs and more 16.07.2022

Listen as Paul Abernathy, Certified Master Electrical Code Professional and CEO and Founder of Electrical Code Academy, Inc. answer more questions submitted through the Let's Ask Paul Portal at www. PaulAbernathy.com . This episode answers the questions about WR Rated Receptacles in damp or wet locations, does Paul accept a former troublemakers apology, and are stud packs, ganged studs, considered...

Let's Ask Paul | Episode 70 | 12 AWG and its amps, Motor Tables, and More 09.07.2022

Join Paul Abernathy for another episode of Let's Ask Paul from www. PaulAbernathy.com . In this episode, Paul answers the question of using motor nameplates versus the tables for full load current, and someone asks about the ampacity of a 12 AWG conductor and how to use the various NEC rules. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/suppo...

Let's Ask Paul | Episode 69 | Helping answer a Real World Transformer Sizing Request 04.07.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question from a submission via the Let's Ask Paul Portal at www. PaulAbernathy.com . This podcast answers a question about sizing a transformer to handle a single HVAC Load and all the things to take into consideration when selecting the proper sized transformer. Become a supporter of this podcast: https://w...

Let's Ask Paul | Episode 68 | Verifying an Electrician's Code References for Fire Incident 26.06.2022

Join Paul Abernathy, CEO, and Founder of Electrical Code Academy, Inc., a premier electrical code training academy located in Texas. Today's question was submitted through the Let's Ask Paul Portal at www. PaulAbernathy.com and it pertains to validation of NEC code references for a fire incident being inspected by the electrician or electrical inspector. Remember, you can submit your own questions...

Let's Ask Paul | Episode 67 | (2) 100A Panels supplied by 125A Main & More 26.06.2022

Join Paul Abernathy, CEO, and Founder of Electrical Code Academy, Inc. as he answers another question from those submitted via PaulAbernathy.com and the Let's Ask Paul Portal. In this episode, Paul answers the question about (2) 100 Amps breakers in a 125A Panel as well as explains straight versus slash-rated circuit breakers. Become a supporter of this podcast: https://www.spreaker.com/podcast/ma...

Let's Ask Paul | Episode 65 | Paul and Jay Talk about the Schneider Load Center Recall 19.06.2022

Listen as Paul Abernathy and Jay Grundberg chat about the recent recall for the Schneider QO with the plug-on neutral load center recall. With over 1.4 million load centers part of this recall, it is bound to be a costly error for Schneider, also known as Square D. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support . Struggling with the Nat...

Let's Ask Paul | Episode 66 | Metal Boxes and Equipment Bonding Jumper Question 19.06.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question submitted via the Let's Ask Paul Portal at www/PaulAbernathy.com. Today's question was about using an equipment bonding jumper from the metal box to the device instead of taking an equipment bonding jumper from the equipment grounding conductor wirenut where all the EGC's are connected. Become a sup...

Let's Ask Paul | Episode 64 | So you wanna be a Electrical Inspector 11.06.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers more electrical code-related questions from folks who submit questions on the Let's Ask Paul Portal a www. PaulAberanthy.com . Today's podcasts answer a question asking for advice on becoming an electrical inspector. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733...

Let's Ask Paul | Episode 63 | Ampacity of NM Cable and Subby's Bruh at Detached Garages 11.06.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers more electrical code related questions from folks who submit questions on the Let's Ask Paul Portal a www. PaulAberanthy.com . Today's podcasts answer a question about the ampacity of Nonmetallic-sheathed cable and another about installing remote distribution panels, sometimes called sub-panels, in detached garages...

Electrify™ | The Master The NEC Mobile App - It's FREE! 08.06.2022

Listen as Paul Abernathy, CEO, and Founder of Electrical Code Academy, Inc. talks about the new APP and all the features that are included. Over 90% of the features on the APP are FREE and designed to help you better understand and utilize the National Electrical Code. You can download the APP free at www. NECCHAT.com Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-...

Let's Ask Paul | Episode 62 | Questions on Exam Prep, Neutral Colors, and Temporary NM Cable 20.05.2022

Listen as Paul Abernathy, Founder and CEO of Electrical Code Academy, Inc. and creator of the Fast Trax® National Electrical Code Learning System answers more questions submitted via PaulAbernathy.com at the Let's Ask Paul Portal. On this episode Paul answers questions on exam prep in the last 2 weeks, questions on stripes on neutrals, and using NM-B in a specific construction environment. Be sure...

Let's Ask Paul | Episode 61 | Sizing Conductors to AC Motor Compressor 14.05.2022

Listen as Paul Abernathy, CEO, and President of Electrical Code Academy, Inc. answers another question submitted via the portal at www. PaulAbernathy.com . This episode answers a submission about conductor sizing for motor compressors for air conditioning systems using the 2020 National Electrical Code. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--10...

Let's Ask Paul | Episode 60 | Explaining Transformer Protection in 450.3(B) 14.05.2022

Listen as Paul Abernathy, CEO, and President of Electrical Code Academy, Inc. answers another question submitted via the portal at www. PaulAbernathy.com . This episode addresses the overcurrent protection rules for transformers found in 450.3(B) of the 2020 National Electrical Code. Become a supporter of this podcast: https://www.spreaker.com/podcast/master-the-nec-podcast--1083733/support . Stru...

Let's Ask Paul | Episode 59 | Understanding 150V or less to ground and 150V or more to ground 08.05.2022

Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. and the creator of the Fast Trax® NEC Learning System. On this episode of Let's Ask Paul, the discussion is about understanding the phrase 150 volts or less to ground and when it says 150 volts or more to ground in the National Electrical Code. If you are interested in the Fast Trax® NEC Learning System to increase your knowledg...

Let's Ask Paul | Episode 58 | Receptacle Spacing, Bus Ratings, and Ranges 08.05.2022

Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. and the creator of the Fast Trax® NEC Learning System. On this episode of Let's Ask Paul, the discussion is about kitchen receptacle spacing, range calculations on an electrical exam and so much more. If you are interested in the Fast Trax® NEC Learning System to increase your knowledge of the National Electrical Code then visit...

Let's Ask Paul | Episode 57 | Conductors at Subby's Bruh and Straight/Slash Rated Breakers 02.05.2022

Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answer questions submitted on PaulAbernathy.com at the Let's Ask Paul. On this episode we answer questions about conductors to remote panels and chats on slash versus straight ratings. Also, you can submit your questions to www. PaulAbernathy.com Become a supporter of this podcast: https://www.spreaker.com/podcast/master-th...